Orders & Worldwide
Orders & Worldwide
If KUKA KSS00021 Bus Communication Error appears, take these immediate actions:
Important: Temporary bus interruptions may clear after restart, but repeated KSS00021 alarms usually indicate hardware, wiring, or controller network faults.
KUKA KSS00021 indicates that the KRC controller has detected a communication failure somewhere within the robot’s internal bus system.
Th is bus system is responsible for transferring data between:
In simple terms: The controller cannot reliably communicate with one or more critical control modules, so robot motion is stopped until communication is restored.
When th is fault occurs, operators may notice:
These symptoms usually indicate a failure somewhere in the robot’s internal communication network.
Damaged wiring can interrupt bus communication:
This is one of the most common causes.
A faulty hardware module may stop responding:
Incorrect settings may disrupt communication:
Communication ports may fail due to:
EMI interference may corrupt communication signals:
Use SmartHMI diagnostics to determine:
Check:
Reconnect all bus-related wiring.
Verify:
Replace non-responsive modules if necessary.
Confirm:
Check:
After repairs:
|
Component |
Description |
Typical Replacement |
|
Bus Communication Cable |
Internal data communication cable |
Shielded Industrial Cable |
|
RDC Module |
Resolver communication board |
KUKA RDC Series |
|
KSP/KPP Drive Module |
Servo drive controller |
KSP/KPP Series |
|
CCU/CIB Board |
Cabinet communication board |
KRC4 CCU/CIB |
If multiple modules go offline at the same time, focuson:
When several modules fail together, the root cause is often upstream—not the individual modules themselves.
Dependingon the cause:
To reduce recurrence:
KUKA KSS00022 Fieldbus Communication Error – Module lost connectionon Fieldbus network.
KUKA KSS00023 Profinet Communication Error – Profinet interface communication lost.
KUKA KSS00024 EtherCAT Communication Error – EtherCAT network module offline.
KUKA KSS00410 X20 I/O Communication Error – X20 module not responding.
KUKA KSS01407 Fieldbus Communication Error – Controller detects communication timeout.
⚠️ Closely related to bus/network communication, module connectivity, and control reliability.
It means the KRC controller detected a failure in internal bus communication with one or more modules.
No. Robot motion is typically blocked until communication is restored.
Typical causes include:
Yes. It can disable robot motion and may indicate larger controller communication issues.
Yes. Repeated communication interruptions may cause:
Explore the Full Guide: Industrial Robot Fault Codes Library → KUKA Error Codes
Explore the complete guide for troubleshooting, repair strategies, and component replacement across industrial robot systems.
Key components commonly involved in kuka error troubleshooting issues and replacements.
{"one"=>"Select 2 or 3 items to compare", "other"=>"{{ count }} of 3 items selected"}
Leave a comment on this topic