Commandes et dans le monde entier
Commandes et dans le monde entier
If KSS00006 appears, go through th is checklist before deep diagnostics:
👉 Field Tip:
If there is no contactor “click” when pressing DrivesON, the issue is almost always upstream (safety or power), not the servo drive.
KSS00006 simply means:
“The controller refused to turn drivesON.”
It doesn’t tell you why.
Before drives can be enabled, the KRC4 checks a full chain:
If any one of these fails, you get KSS00006.
KUKA KSS00006 is a controller-level status error indicating that the KRC4 cannot activate the servo drives because one or more required enable conditions are not satisfied.
When th is error is active:
The controller only enables drives after confirming:
Operators commonly report the following:
Field Tip:
If the robot boots normally but the drives never energize, KSS00006 often points to an enable-chain interruption rather than a failed servo drive.
This is the #1 reason.
Typical triggers:
Drives will never enable until safety is 100% valid.
In manual mode, this is very common.
If no enable signal → no drives.
If you press DrivesON and hear nothing:
This is a classic “no click = upstream issue” situation.
Sometimes the drives themselves are the blocker.
Check LEDs before replacing anything.
KRC4 must finish startup first.
Drives won’t enable if the system isn’t fully ready.
|
Component |
Description |
Use Case |
|
KSP Servo Drive Modules |
axis drive modules |
Replace if LEDs indicate fault or KRC shows drive error |
|
KPP Power Modules |
Power supply for servo drives |
Faulty or unresponsive power modules |
|
Teach Pendant / SmartPAD (00-168-334) |
Deadman / enabling switch |
Replace if deadman switch fails to signal enable |
|
Safety Relays & Contactors |
Pilz / Sick certified |
Restore safety-to-drive signal path |
|
Main Contactors & Power Supply Units |
High-current switching |
Repair unstable drive power conditions |
|
Safety PLC / SIB/CIB Modules |
Safety interface boards |
Faults causing drive enable blockage |
⚠️ Compatibility Tip: Verify KRC4 version, KSP/KPP firmware, and SmartPAD revision before replacing components.
From real maintenance cases, these are the parts most often involved:
|
Component |
When to Suspect It |
|
SmartPAD (00-168-334) |
Deadman not responding |
|
KPP Power Module |
No power / contactor issues |
|
KSP Servo Module |
Drive not ready |
|
Safety Relay / Contactor |
No “click” on DrivesON |
|
SIB / CIB Module |
Safety chain won’t close |
Experienced technicians often diagnose KSS00006 by tracing the full enable chain:
Drive Enable Logic Path:
Safety → Controller Logic → DrivesON Signal → Main Contactor → KPP → KSP → Servo Ready
Helpful checks include:
Field Tip:
If pressing “DrivesON” produces no click from the contactor, the problem is usually upstream—not inside the servo drive.
Dependingon root cause:
Reduce future KSS00006 faults with routine maintenance:
Recommended Inspection Schedule:
⚠️ Technical Note: KSS00006 is often a secondary symptom of unresolved safety or power conditions.
One or more drive enable conditions are still not satisfied, such as safety, power, or communication readiness.
Not necessarily. Most cases are caused by safety chain or enable logic issues rather than failed drives.
The controller requires valid safety signals, completed startup, functional power supply, and ready KSP/KPP modules.
Clear all related faults, verify enable conditions, then restart and press DrivesON again.
KUKA KSS00006 is a drive enable status fault indicating that the controller cannot activate the servo system.
Because It is usually a secondary alarm, the true root cause is often found upstream in the safety chain, power circuit, enable logic, or startup sequence.
A systematic troubleshooting process—following the drive enable chain from safety input to servo output—is the fastest way to isolate and resolve the issue.
Explore the Full Guide: Industrial Robot Fault Codes Library → KUKA Error Codes
Explore the complete guide for troubleshooting, repair strategies, and component replacement across industrial robot systems.
Key components commonly involved in kuka error troubleshooting issues and replacements.
{"one"=>"Sélectionnez 2 ou 3 articles à comparer", "other"=>"{{ count }} éléments sélectionnés sur 3"}