Error Code: KSS01305
-
Category: Power Supply / Drive System
-
Severity: High
-
System: KRC4 / KSP Drives
-
Impact: axis disabled, robot stops, possible
drive protection triggered
Quick Fix for KUKA KSS01305
If the robot suddenly stops with th is
error:
- Reset the controller and observe if the error returns
- Check incoming power supply (voltage drop or instability)
- Inspect KSP drive LEDs for faults
- Verify all power and motor cables are firmly connected
- Run the robot at lower speed and acceleration
⚠️ Always power down before checking
cabinet power or drive wiring.
👉 If the robot runs fine at low
speed but trips during acceleration, the issue is usually power-related or
load-related.
What Is KUKA KSS01305?
KSS01305 is triggered when the DC bus
voltage falls below the minimum threshold required by the KSP drives.
The DC bus is critical because it:
- Supplies energy to all servo drives
- Maintains stable torque output
- Supports multi-axis coordinated motion
When voltage drops:
- Drives cannot maintain torque
- Axes lose stability or stop
- The system shuts down to prevent damage
Typical Symptomson Site
- Robot stops during acceleration or heavy motion
- Axes fail to enable after startup
- SmartHMI shows KSS01305 repeatedly
- KSP drives indicate fault (often after motion start)
- Motion becomes unstable before stopping
👉 A key pattern: works at idle → fails under load
Common Causes for KUKA KSS01305
1. Incoming Power Instability
Most frequent root cause.
- Voltage dips from plant power
- Weak or overloaded power line
- Loose cabinet input wiring
👉 Especially common in factories
with large equipment switchingon/off
2. DC Bus Capacitor Aging
Over time, capacitors lose capacity.
- Reduced energy buffering
- Voltage drops under load
- Intermittent undervoltage alarms
👉 Very commonon older KRC4
cabinets
3. KSP Drive Internal Issues
- Drive not handling bus voltage correctly
- Internal protection triggered
- Overheating affecting performance
4. High Load / Aggressive Motion
- Heavy payload
- High acceleration settings
- Multiple axes moving simultaneously
👉 Causes sudden current demand →
voltage dip
5. Power Cable or Connection Problems
- Loose terminals
- Worn motor power cables
- High resistance connections
6. Parameter or Firmware Issues
- Incorrect DC bus thresholds
- Firmware mismatch between KRC4 and KSP
- Corrupted drive parameters
How to Troubleshoot KUKA KSS01305
Step 1 – Check Incoming Power
- Measure input voltage at cabinet
- Look for voltage drop during motion
- Inspect main contactor and fuses
Step 2 – Monitor DC Bus Voltage
Use:
SmartHMI → Drive Diagnostics → DC
Bus
- Observe voltage in real time
- Check if it drops during acceleration
Step 3 – Inspect KSP Drives
- Check LED status
- Identify which drive is affected
- Swap modules if necessary
Step 4 – Check Cables & Connections
- Tighten all power connections
- Inspect motor cables for wear
- Check grounding and shielding
Step 5 – Reduce Load and Test
- Remove payload if possible
- Lower speed and acceleration
- Run test cycle
👉 If stable at low load → problem is power or capacity
Step 6 – Replace Faulty Components
If issue persists:
- Replace DC bus capacitors or power modules
- Replace KSP drive
- Replace damaged cables
Recommended Replacement Parts
-
KUKA KSP 600-3x20 Servo Drive (00-198-265): For internal bus or electronics faults.
-
Main Contactor or DC Bus Capacitors (KUKA OEM spec): To restore bus stability.
-
Motor Power Cables and Connectors (High-flex, Shielded): To prevent voltage drop or disconnection.
-
Power Supply Monitoring Modules: For early
detection of undervoltage events.
⚠️ Compatibility Tip: Confirm
robot serial number, axis number, and KSS version before replacing drives or
power components.
Pro Diagnostic Tip for KUKA KSS01305
- Navigate to SmartHMI → Drive
Diagnostics → DC Bus Monitoring.
- Monitor bus voltage and current in real-time.
- Log undervoltage events to identify intermittent power drops.
- Check for correlation with high-torque operations or multiple axis
movements.
- Repeated KSS01305 often indicates aging capacitors or unstable cabinet
power.
How to Fix KSS01305
- Stabilize incoming power supply
- Replace aging DC bus components
- Repair or replace power cables
- Reduce load or optimize motion profile
- Replace faulty KSP drive if needed
Prevention & Maintenance
- Regularly inspect cabinet power supply and DC bus components.
- Maintain stable incoming voltage.
- Ensure proper ventilation and cooling of drives.
- Avoid overloading axes or sudden acceleration spikes.
- Replace aging KSP drives proactively.
Related KUKA Errors
⚠️ Technical Note: DC bus
undervoltage often triggers or correlates with:
-
KSS01306DC Bus Overvoltage Error –
Bus voltage excursions beyond safe limits.
-
KSS00401Motor Error– Drive/motor
current interruptions caused by undervoltage.
-
KSS01404Servo Drive Error– KSP
drive internal faults linked to DC bus issues.
-
KSS00406Position Deviation Error–
Undervoltage causing torque loss and axis deviation.
FAQ About KUKA KSS01305
What does KUKA KSS01305 mean?
It indicates the DC bus voltage supplying
the servo drives dropped below safe levels, stopping axis motion.
Can the robot operate with DC
Bus Undervoltage?
No. Drives may be disabled and motion
blocked until voltage stabilizes or components are repaired.
How do I fix KUKA DC bus
undervoltage errors?
Check cabinet power, inspect drives and
motor connections, monitor DC bus voltage, and replace faulty components if
needed.
Can heavy payload or
acceleration cause KSS01305?
Yes. Excessive load or sudden motion can
temporarily lower bus voltage, triggering the error.
Leave a comment on this topic