The Yaskawa control boards are the heart of
all Yaskawa Motoman robot controllers, including the YRC1000, NX100, NX200, and
GP-series.
These boards manage motion
control, I/O communication, servo coordination, safety monitoring, and
human-machine interface operations, making them critical for continuous
industrial automation.
This index provides a structured overview of the main control board categories, typical part numbers, failure symptoms, and replacement guidance for Yaskawa robots.
Why Control Boards Matter
Control boards handle the "brain" and "nervous system" of your robot. Board failures are often the root cause of:
- Robot downtime and production stoppages.
- Servo or axis errors preventing motion.
- Communication failures between the controller, robot, and PLC.
Having a comprehensive parts index allows maintenance teams to quickly identify and replace faulty boards.
Main Categories of Yaskawa Control Boards
1. CPU & Main Logic Boards
Responsible for robot program execution, motion planning, and system management.
Below are typical CPU and main logic boards used in YRC1000, NX100, and NX200 controllers.
| Part Number | Compatible Controller | Function |
|---|---|---|
| JANCD-YCP01 | YRC1000 | Main CPU & Communication Board. |
| JANCD-YCPU2 | YRC1000 | Secondary CPU / Logic Board. |
| JZRCR-NRK01 | NX100 | Core processor module. |
| JANCD-CPU02 | NX200 | Main Processing Board. |
- Symptoms of failure: Controller fails to boot, program execution errors, system freezes.
2. Servo Communication & Amplifier Interface Boards
Manages high-speed communication between the controller and the servo drives.
| Part Number | Compatible Controller | Function |
|---|---|---|
| JANCD-YCM01 | YRC1000 | Servo Communication Board. |
| JANCD-SCM01 | NX100 | Servo Control Module. |
| JANCD-SCM02 | NX200 | Servo Interface Board. |
- Symptoms of failure: Axis servo alarms, communication errors, loss of motion control.
3. Digital / Analog I/O Boards
| Part Number | Compatible Controller | Function |
|---|---|---|
| JANCD-YIO21 | YRC1000 | Digital I/O Board. |
| JANCD-YAIO1 | YRC1000 | Analog I/O Board. |
| JANCD-IOD01 | NX100 | Digital/Analog I/O Board. |
- Symptoms of failure: Sensors/actuators not responding, PLC communication errors.
4. Fieldbus & Network Interface Boards
| Part Number | Compatible Controller | Function |
|---|---|---|
| JANCD-YNi01 | YRC1000 | Network Interface (Ethernet/IP, PROFINET). |
| JANCD-FB01 | NX100 | Fieldbus Communication Module. |
| JANCD-FB02 | NX200 | Industrial Network Board. |
Symptoms of failure: Network communication drops, fieldbus device errors.
5. Safety & Relay Boards
| Part Number | Compatible Controller | Function |
|---|---|---|
| JANCD-YSR01 | YRC1000 | Safety Relay Board. |
| JANCD-SRB01 | NX100 | Safety Logic & Relay Board. |
| JANCD-SRB02 | NX200 | Safety Relay & Interlock Board. |
Symptoms of failure: E-Stop not responding, unexpected motion lockouts.
6. Power Supply & Backup Boards
| Part Number | Description |
|---|---|
| JANCD-YPS01 | YRC1000 Main Power Supply Board |
| NX100-PS01 | NX100 Power Module |
| NX200-PS02 | NX200 Backup / Redundant PSU |
Symptoms: Controller
wont power on, Random shutdowns or resets, Voltage or temperature alarms
Related Yaskawa Spare Parts Index Pages
- Yaskawa YRC1000 Spare Parts List
- Robot I/O Modules & Expansion Cards Index
- Robot Fieldbus & Network Interface Index
- Robot Servo Drives Master Index
- Robot Battery Packs & Backup Units Index
These indexes together provide a complete Yaskawa robot maintenance and spare parts hub.
FAQ C Yaskawa Control Boards
Q1: Can YRC1000 boards be used in NX100 or NX200 controllers?
A: No. Each controller generation uses unique architecture, firmware, and connectors; boards must match the controller model.
Q2: Which control boards fail most often?
A: Servo communication, I/O, and power supply boards are most frequently replaced due to industrial load and wear.
Q3: Are refurbished boards reliable?
A: Yes, when tested for functionality, communication, and safety compliance, refurbished boards provide a cost-effective solution.
Q4: How do I identify the correct board for replacement?
A: Always verify the board part number printed on the board and cross-reference with the robot series and controller firmware.